DaVinci Configurator Classic Release 6.3
Tool Features
Other
-
(„Preview of 2027 product version“) Provide MCP Tools for the DaVinci Assistant’s Use-Cases (ADF-15564)
-
Deactivating a derived module configuration now completely removes the module from the model rather than just removing it from the active module configuration collection. (ADF-14563)
-
Enhance run-script command to allow multiple files as input (ADF-13918)
-
Hints for usage of EcuXPro Analyze command (ADF-14495)
-
Provide a way to open a project and remembering the settings to do so (ADF-15562)
-
Provide an interactive Migration for DaVinci Configurator Classic 5 projects (ADF-14764)
-
Separate Derivation Rules from the DaVinci Configurator Classic and move them to the Bsw Package (ADF-11236)
-
Support AUTOSAR Schema 25-11 (ADF-14429)
Fixed Issues
Other
-
All loaded directories from ArxmlProjectContent.json are now supervised by file supervision. This should improve the external file change events dialog and prevent working on an outdated model. (ADF-14922)
-
ChangedRecommendedValue annotation not created for objects already in user ecuc (ADF-14560)
-
Component Connection Assistant Exception (ADF-14374)
-
Derive-EcuC fails for Postbuild-Selectable projects with variant communication clusters in combination with multi-driver mappings (ADF-15207)
-
During project mogration, absolute path entries in the <Display> section of the dpa file are handled correctly. (ADF-14606)
-
EcuXPro command for LegacyConverter execution overwrites files for multiple variants (ADF-14455)
-
Fixes an exception when connecting Service Ports in a variant project. (ADF-15185)
-
Fixes an incorrect "Execution Order Constraints feature is not yet supported" error in TaskMappingAssistant. (ADF-14974)
-
Fixes an issue where a container is shown twice. (ADF-14759)
-
Fixes an issue where connections are dropped when DataPrototypeMappingReferences is provided with PortInterfaceMappings with identical PortInterfaces. (ADF-15089)
-
Fixes derivation of Post-Build Selectable variants projects which may miss configuration data in some variants and may get unintended variant configuration in the ECU-C. (ADF-14913)
-
Incorrect default value derived for 1939Tp[Rx|Tx]ChannelUsesMultiPG (ADF-14595)
-
J1939TpChannels are not derived for Rx and Tx without Transmitter in J1939TpConnection (ADF-14688)
-
Modification of derived recommended float parameters incorrect (ADF-14738)
-
Non-default EcuC splitter file locations and their configurastion entries are now correctly migrated. (ADF-14502)
-
Possible conflict of implementation variants definitions during project load when using the EcuC derivation as well as the diagnostic module import in Post Build projects (ADF-14800)
-
Unable to create parameters in DDM created containers (ADF-14559)
-
Workaround to manually set or adapt the ECU-EXTRACT-REF is no longer necessary. A solving action is now available to correctly set the reference. (ADF-14478)
-
Wrong Criterion Reference in Variant Extract after variant-merge of EcuXPro (ADF-14355)